Figure 49: Battery

WARNING: Before continuing with this procedure, review the Warning and
Caution statements listed in the Warning and Caution Statements and
General Safety Guidelines Section, Things You Should Know.
3 Set the ohmmeter to a range that will conveniently read up to 50 Ω
(Ohms).
4 Remove the two wires from the LOAD terminals of the lower PCA.
5 With an ohmmeter, read between the wires removed in step 4. The
reading should be approximately 10 Ω (Ohms). Replace the two wires
removed in step 4.
6 Remove the three wires from the 3 PHASE GEN IN terminals of the
lower PCA.
7 With an ohmmeter, read between the red & white, red & black and
white & black wires. Each reading should be approximately 25 Ω
(Ohms). Reconnect the wires removed in step 6.
8
If the readings are still incorrect, replace the three phase
generator.
9 Reconnect the red battery wire removed in step 3.
10 Replace the right side cover as per,
.