Page 1
Warning: This service manual is for use by Precor trained service providers only. If you are not a Precor Trained Servicer, you must not attempt to service any Precor Product; Call your dealer for service. This document contains information required to perform the majority of troubleshooting, and replacement procedures required to repair and maintain this product.
Page 3
Do not use accessory attachments that are not recommended by the manufacturer-such attachments might cause injuries. General Information For the latest exploded view, part number and part pricing information, visit the Precor dealer website at www.precor.com/connection. Tools Required Multimeter...
Page 12
5. A software package or list of software packages will be displayed on the P80 console screen. Touch the spot on the P80 console screen displaying the software package required. Note: PRECOR customer service will specify which software package is required when the service is requested to update P-80 Console software. If you are unsure of which software package should be installed, contact PRECOR customer service.
Page 17
EFX 885, 835, 825 Service Manual 20039-166 Procedure 3.7 P80- Connectivity Configuring your audio, video, and network infrastructure requires expertise. Precor strongly recommends that you work with a qualified contractor to set up this infrastructure. This setting provides the following information: ...
Page 18
Connectivity Set Up and Registration Procedure Before you attempt to connect to the Precor Preva Server, check the status field and ensure that the Connected is displayed. If the Status field shows Not Connected, you will need to diagnose your networking issue. Continue with Step 2.
Page 20
15. A screen will appear stating, The equipment is ready to be set up, touch USER NAME AND PASSWORD. 16. The user name and password will have been provided by Precor prior to installation. Enter the user name using the on-screen keypad, then touch NEXT.
Page 39
Precor splash screen. Perform a 7 Power Cycle (See Boot Screen Procedure below) to force the machine to revert to the backup image. When the unit boots successfully, reflash the unit with the correct software to ensure that the old, corrupted image has a usable image installed.
Page 57
Procedure: 1. The EFX 885 and 835 uses the standard access codes to provide access to the various software features. Use the PAUSE key and the numeric keypad to enter the access code. The standard access codes use all sequential key presses.
Page 82
Precor or it may be downloaded to the PDA from your desktop or laptop computer via the hot sync function. With the PDA inserted in the hot sync cradle, download to Precor IFP (in field programmer) directory.
Page 86
10. If 8 Vdc is not present on TP4 and the upper PCA is illuminating normally, replace the cable between the upper PCA and the metrics PCA. 11. If you have performed steps 7 - 10 and the metrics PCA still does not illuminate, contact Precor customer support for assistance.
Page 87
30. If the STUCK KEY is still being displayed with the keyboard cable disconnected, replace the upper PCA. 31. If you have performed steps 23 - 30 and the STUCK KEY message is still being displayed, contact Precor customer support for assistance.
Page 92
10. Troubleshoot the upper to lower PCA interconnect cables per Procedure 9.1. 11. If the upper to lower interconnect cables are found to be good, replace the upper PCA. 12. If you have performed all of the above tests and are unable to resolve the problem, contact Precor customer support.
Page 121
10. If 5 Vdc is present on C5 and the upper PCA is illuminating normally, replace the metrics PCA. 11. If you have performed steps 7 - 10 and the metrics PCA still does not illuminate, contact Precor customer support for assistance.
Page 122
21. If the display face has been replaced and the same key or control is still not functioning, replace the upper PCA. 22. If you have performed steps 18 - 22 and the same key is still not functioning, contact Precor customer support for assistance.
Page 126
Start striding on the EFX or plug the optional external power supply (when available) into the EFX and the AC outlet. 2. When the PRECOR banner displayed, press GO (P80) or QUICK START (P30). 3. Select Resistance Level 1. 4. Operate the EFX for 4 5 minutes. As you operate the EFX, concentrate on the operating sounds made by the unit.
Page 134
Connect a replacement mid-point connector between the two interconnect cables and retest the unit per Procedure 10.4. 11. If you have performed all of the procedures above and have been unable to correct the problem, call Precor customer support.
Page 135
100 VAC -110 VAC. 3. If any of the six readings in step 2 are significantly low, replace the generator. 4. If you have performed all of the above tests and are unable to resolve the problem, contact Precor customer support.
Page 137
10. Verify that all of the wires in the intermediate cable (the cable inserted in to J3 of the lower PCA) are securely inserted into the connector housing and providing a good electrical connection. 11. If you have performed all of the above tests and are unable to resolve the problem, contact Precor customer support 12.
Page 144
8. Remove the ground lead of the wrist strap from the EFX frame, and then remove the wrist strap from your arm. 9. Re-install the rear cover, and then check the operation of the EFX 885, 835 as described in Section Seven. Page 144...