11 Reconnect the Data cable, Auto Stop cable (Treadmill only), Stop Key
cable (Treadmill only), Heart Rate ground wire and the CSAFE cable
(if in use) from the Upper PCA.
12 Reconnect the Heart Rate Cable to the Heart Rate PCA.
13 Replace the Heart Rate PCA. See
14 Replace the access cover..
15 Tilt the console back against the mounting plated. While tilting the
console back feed the excess cable into weldment tube making sure
that the cables will not become pinched.
16 Fasten the console to the dash mounting plate with the four screws.
17 Fasten the dash transition cover using the two screws (TRM only)
18 Check treadmill operation per

Replacing the P30 HR PCA

1 Set the treadmill circuit breaker in the off position and unplug the
treadmill's line cord from the AC outlet.
2 The PCA's in the console are static sensitive. They can be damaged
if proper static prevention equipment is not used. Attach an anti-
static wrist strap to your arm, and then connect the ground lead of
the wrist strap to the treadmill's frame ground.
3 Remove the HR PCA access panel on the back of the console.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law

Replacing the P30 HR PCA

Checking the AMT Operation
(on page 37).
(on page 125).