Console Mounting - Install; Replacing The P80 Heart Rate Pca Board; Figure 43: P80 Heart Rate Cable Routing - Precor AMT Series Service Manual

Table of Contents

Advertisement

Figure 43: P80 Heart Rate Cable Routing

Console Mounting - Install

1 Make sure that all cables are fully and securely connected, and that
cables are tied back properly.
pulled down through the neck and along the front of the dash, making
sure the cables are routed through the plastic guides inside the
neck.
2 Tilt the control console backward (toward yourself) until the tab on
the top edge of the armor slides along the top edge of the console
mount and the screw holes align properly.
3 Secure the console to the plate using the four flat head
screws.
Note: You must use
console will not be properly grounded. If the screws are too long it is
4 Tighten the screws fully using a ⁵/₃₂-inch hex wrench.
possible to damage the internal wiring.
5 Replace the rear vent cover.

Replacing the P80 Heart Rate PCA Board

Procedure
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Make sure any extra cabling is
/
inch long screws. If the screws are too short the
5
8
5
/
inch long
8
Page 102

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amt 835Amt 885Amt 833Amt 823

Table of Contents