49 At the console enter the access code PAUSE,5,1,7,6,5,7,6,1, to enter
into the diagnostics software. Navigate to the STRIDE COUNT RESET
section and reset the flat belt stride count.
50 Replace the main body covers as per procedure,
page 152).
51 Check the operation of the AMT12.
Replacing the Front Arm Assemblies - With Flat Belts and
Press Fit Cams (After 4/3/2013)
1 Standing at the front of the AMT, push in and then downward on the
cover gasket with your thumbs until the gasket locking tabs are free
of the top cover, grasp the gasket and remove. The gasket is split
at the back to facilitate removal.

Figure 154: Cover Gasket

2 Grasp the top cover at the gasket opening and pull upward to apply
pressure to the locking tabs. While pressure is applied to the top
cover gently tap the front cover just below the top cover with the
heel of your hand. See figure below.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Cover Replacement