Procedure; Figure 52: Generator Belt - Precor AMT Series Service Manual

Table of Contents

Advertisement

Procedure

1 Remove the gasket, top, front, rear, left and right side covers per
procedure,
2 Place a belt gauge on the generator belt as shown in below.

Figure 52: Generator Belt

3 The belt gauge should read approximately 85 ±5 lbs. If the belt
tension is significantly high or low the belt tension may be
adjusted by loosening the generator mounting bolts.
4 Loosen or tighten the generator adjustment nut and bolt until the
belt gauge reads approximately 85 ±5 lbs.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Cover Replacement
(on page 152).
Page 131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amt 835Amt 885Amt 833Amt 823

Table of Contents