Replacing The Drive Input Housing; Drive Input Housing Replacement Procedure; Figure 272: Gas Shock - Precor AMT Series Service Manual

Table of Contents

Advertisement

Figure 272: Gas Shock

Caution: It is recommended to have assistance available for following
step(s).
50
With the assistance, lift the front of the Incline platform until
the Incline tube mounting holes align with the Incline platform
mounting holes.
51 Replace the Incline motor mounting pin through the Incline tube and
Incline platform and attach the hitch pin.
52 Replace the wave washer and flat belt pulley, secure the flat belt
pulley with the snap ring.
53 Secure the flat belt clamps the lift arm housing using the four 3/8-
16 X 3 mounting bolts and washers.
54 Lift the stairarms and thread the flat belts through the pulleys.
55 Replace the covers as per procedure,

Replacing the drive input housing

Drive Input Housing Replacement Procedure

1 Remove the covers as per procedure,
2 Remove the tension from the inner flat belt pulleys by lifting up on
the stairarms, pulling the flat belts off the flat belt pulleys, and
then gently setting the stairarm down.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law