11 Disconnect the data cable, incline motor cab le (Open Stride only),
generator cable, load cable, stride dial cable, battery cables, and
vertical sensor cable from the lower PCA.
12 Secure the cables wires into the mounting clamps on the lower PCA
battery bracket.
Note: Ensure that the wires are not pinched between the lower PCA bracket
cover and the lower PCA battery bracket.
13 Replace the lower PCA cover as per procedure,
"Removing the Lower PCA
14 Replace the covers as per procedure,

Replacing the Battery

Procedure

1 Remove the covers as per procedure,
2 Remove the lower PCA cover.
PCA
Cover" on page 268)
3 Disconnect the two battery cable connectors from the battery
terminals.
4 Set the replacement battery in the lower PCA bracket with the
battery terminals facing out.
5 Connect the red wire battery cable to the terminal on the battery
marked with a (+) or red square.
6 Connect the black wire battery cable to the terminal on the battery
marked with a (-) or black square.
7 Replace the lower PCA cover.
8 Replace the covers as per procedure,