Figure 60: Incline Motor Hitch Pin and Mounting Pin

8 Access the incline Lift Test portion of the Diagnostic Program, see
Accessing the P30 Diagnostic Software
51).
9 With the lift incline number displayed, set
using the STRIDE HEIGHT  and STRIDE HEIGHT  keys
10 Rotate the incline motor tube on the incline motor drive screw until
the measurement between the top of the incline nut and the end of
the incline motor drive screw is 1-1/4 inches.
Note: When rotating the incline motor tube, do not allow the incline
motor drive screw to rotate. If the incline motor drive screw rotates, the
lift level number will change. The lift level number must be 2 and the
physical measurement must be 1-1/4 inches for the calibration to be
correct.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
P80 Settings
(on page 13),
the incline to level 2
(on page