39 Lift the stairarms and then thread the flat belts over the flat belt
pulleys.
40 Select the QUICKSTART program
resistance level 10 is displayed. Pedal the AMT for approximately
one minute, then recheck the belt tension.
Figure 269: Generator
41 The drive input belt tension should read approximately 135 ±5 lbs
and the generator belt tension should read approximately 85 ±5 lbs.
Drive Belt Gauge Instructions
See
Incline Motor Installation
42 Attach the replacement Incline motor to the frame using the 3/8-16
mounting bolt.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
and adjust the resistance key until
(on page 142)