H parameters assign functions to the multi-function input and output terminals.
u

H1: Multi-Function Digital Inputs

No.
(Addr.
Name
Hex)
Multi-Function Digital
H1-01
Input Terminal S1
(438)
Function Selection
Multi-Function Digital
H1-02
Input Terminal S2
(439)
Function Selection
Multi-Function Digital
H1-03
Input Terminal S3
(400)
Function Selection
Multi-Function Digital
H1-04
Input Terminal S4
(401)
Function Selection
Multi-Function Digital
H1-05
Input Terminal S5
(402)
Function Selection
Multi-Function Digital
H1-06
Input Terminal S6
(403)
Function Selection
Multi-Function Digital
H1-07
Input Terminal S7
(404)
Function Selection
<1> Value in parenthesis is the default setting when a 3-Wire initialization is performed (A1-03 = 3330).
H1-oo
Function
Setting
0
3-Wire sequence
Multi-Step Speed
3
Reference 1
Multi-Step Speed
4
Reference 2
6
Jog reference selection
Accel/decel time
7
selection 1
Baseblock command
8
(N.O.)
Baseblock command
9
(N.C.)
A
Accel/decel ramp hold
Drive overheat alarm
B
(oH2)
Analog terminal input
C
selection
204
LCD Display
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S1 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S2 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S3 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S4 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S5 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S6 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S7 Func Sel
Note:
H1 Multi-Function Digital Input Selections
LCD Display
Closed: Reverse rotation (only if the drive is set up for 3-Wire sequence)
3-Wire Control
Terminals S1 and S2 are automatically set up for the Run command and Stop
command.
When input terminals are set to Multi-Step Speed References 1 through 3,
Multi-Step Ref 1
switching combinations of those terminals will create a multi-step speed sequence
using the frequency references set in d1-01 through d1-08.
When input terminals are set to Multi-Step Speed References 1 through 3,
Multi-Step Ref 2
switching combinations of those terminals will create a multi-step speed sequence
using the frequency references set in d1-01 through d1-08.
Closed: Jog frequency reference (d1-17) selected. Jog has priority over all other
jog Freq Ref
reference sources.
Used to switch between accel/decel time 1 (set in C1-01, C1-02) and accel/decel
Multi-Acc/Dec 1
time 2 (set in C1-03, C1-04).
Ext BaseBlk N.O.
Closed: No drive output
Ext BaseBlk N.C.
Open: No drive output
Open: Accel/decel is not held
Acc/Dec RampHold
Closed: The drive pauses during acceleration or deceleration and maintains the
output frequency.
OH2 Alarm Signal
An external device has triggered an oH2 alarm.
Open: Function assigned by H3-14 is disabled.
Term AI Enable
Closed: Function assigned by H3-14 is enabled.
Description
204
to
207
for descriptions of setting values.
Set unused terminals to F.
204
to
207
for descriptions of setting values.
Set unused terminals to F.
204
to
207
for descriptions of setting values.
Set unused terminals to F.
204
to
207
for descriptions of setting values.
Set unused terminals to F.
204
to
207
for descriptions of setting values.
Set unused terminals to F.
204
to
207
for descriptions of setting values.
Set unused terminals to F.
204
to
207
for descriptions of setting values.
Set unused terminals to F.
Description
YASKAWA SIEP YAIZ1U 03B YASKAWA AC Drive – Z1000 Programming Manual
Values
Page
Default: 40 (F)
<1>
72
Min.: 1
Max.: B2
Default: 41 (F)
<1>
72
Min.: 1
Max.: B2
Default: 24
Min.: 0
72
Max.: B2
Default: 14
Min.: 0
72
Max.: B2
<1>
Default: 3 (0)
72
Min.: 0
Max.: B2
<1>
Default: 4 (3)
72
Min.: 0
Max.: B2
<1>
Default: 6 (4)
72
Min.: 0
Max.: B2
Page
73
73
73
73
74
74
74
74
74
74

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-zu series

Table of Contents