6.
Press
to run the motor at 5 Hz. The RUN light will turn on.
With SW1 closed, the drive runs the motor at Multi-Step Speed 2
7.
(20 Hz).
With SW1 open and SW2 closed, the drive runs the motor at Multi-Step
8.
3 (50 Hz).
With both SW1 and SW2 closed, the drive runs the motor at Multi-Step
9.
4 (60 Hz).
STOP
10. Press
to stop the drive. The RUN light will flash until the
motor comes to a complete stop.
<1>
When the frequency reference is assigned to the LED operator (b1-01=0), the first step in a multi-step speed
sequence comes from d1-01.
Note:
When a run command is input from the control circuit terminal, the frequency reference value is selected
as follows:
When b1-01 = 0 and the run command is given, the drive uses the frequency set to d1-01.
When b1-01 = 1 and the run command is given, the drive uses the frequency reference value input to analog
control terminal A1.
u

Drive Input Voltage Setting: E1-01

Set E1-01 according to the power supply voltage. This setting serves as a base value for certain
drive protective functions.
NOTICE: Set drive input voltage (not motor voltage) in parameter E1-01 for proper function of the protective
features of the drive. Failure to comply could result in improper drive operation. Set parameter E1-01 to match
the input voltage of the drive.
Parameter
Name
Set to the nominal voltage of the incoming line. Sets
Input
the maximum and base voltage, and adjusts the levels
E1-01
Voltage
of drive protective features (e.g., overvoltage, braking
Setting
resistor level, stall prevention, etc.).
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Step
Description
4.5 Basic Operation
Display/Result
STOP
Off
On
STOP
Flashing
Off
Setting Range
200 V Class: 155 to 255
400 V Class: 310 to 510
4
Default
200 V
99