Installing and Removing the I/O-IPC

The I/O-IPC has an elevated generation of heat. Excess heat is drawn off by
passive heat dissipation (aluminum underside of the I/O-IPC and mounting rail).
For this reason, the I/O-IPC shall always be mounted on a mounting rail.
6.1

Instructions for Installation/Removal

The following information shall always be observed:
Pos: 36.2 /Serie 758 (Funk, IPC und PFC)/Montieren/Montage 758-87x Sicherheitshinweis Achtung: Belüftung des Einbauorts 55° @ 10\mod_1313494510284_21.doc @ 77072 @ @ 1
Ventilation of the installation site
When installing the I/O-IPC, leave a free space on the sides and above of 40 mm
to achieve sufficient heat dissipation. The surrounding temperature at the
installation site shall not exceed +55 °C during operation.
Pos: 36.3 /Serie 758 (Funk, IPC und PFC)/Montieren/Montage 758-87x Sicherheitshinweis ESD: Offene Schnittstelle @ 10\mod_1313494519690_21.doc @ 77076 @ @ 1
Open interface!
Unneeded interfaces of the I/O-IPC shall be closed with the accompanying
protective caps to prevent possible damage caused by electrostatic discharge.
Pos: 36.4 /Serie 758 (Funk, IPC und PFC)/Montieren/Montage 758-87x Einleitungsende 3 @ 10\mod_1313488048409_21.doc @ 77064 @ 22 @ 1
Select a sufficiently stable mounting rail and use several mounting points
(every 20 cm), if applicable, to prevent the I/O-IPC from bending and
twisting the mounting rail.
When using mounting rails with a height of 7.5 mm, use flat riveting or
sunken screws. Otherwise, the I/O-IPC and the connected I/O modules
cannot be correctly mounted on the mounting rail.
Take care that the physical interfaces are not soiled during installation. This
can lead to damage and corrosion of the contacts.
To avoid damage to the I/O-IPC, do not install it within the shear ranges of
mobile systems or machine parts.
Arrange for an appropriate potential equalization in your system.
The mounting rails shall be screwed on so that they are grounded at the
installation site.