Table 35: Description of the Screensaver and Cleanmode parameters on the "HMI Settings" page
Touchscreen Configuration
Device-Name
Driver-Name
Execute calibration of
touchscreen at next
start
Keyboard Layout
German
English
Pos: 44.4 /Serie 758 (Funk, IPC und PFC)/Konfigurieren/Konfigurieren 785-87x - allgemein 4 @ 12\mod_1331131729572_21.doc @ 90419 @ 3 @ 1
9.1.10

"Administration" Page

The "Administration" page is used to save all settings made to a CF card, the
internal memory of the I/O-IPC or USB storage.
Manual
Version 1.0.0
This is where you select a touch screen (mouse dev) connected via USB.
The I/O-IPC does not support serially connected touch screens.
If a selected touch screen is no longer connected, the message "not
available" will appear here.
This is where you select a device driver for the previously-selected touch
screen.
If you activate this option, when you restart the I/O-IPC, an interface for
calibrating the touch screen will appear before executing the SPS program.
Touchscreen
If no touch screen is connected to the I/O-IPC, this option
must remain deactivated since otherwise the SPS program
will not start.
Select either an English or German keyboard layout for the Linux console
here.