Alarm Types
Accounting Alarms
Accounting server not reachable
TABLE 3 Accounting server not reachable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Accounting failed over to secondary
NOTE
This alarm is not applicable for vSZ-H.
TABLE 4 Accounting failed over to secondary alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Accounting fallback to primary
NOTE
This alarm is not applicable for vSZ-H.
TABLE 5 Accounting fallback to primary alarm
Alarm
Alarm Type
58
Accounting server not reachable
accSrvrNotReachable
1602
Major
An alarm is raised for every event from the event code 1602. A single event
triggers a single alarm.
"mvnoId"=12, "ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="radiusd",
"realm"="wlan.3gppnetwork.org", "radProxyIp"="7.7.7.7",
"accSrvrIp"="30.30.30.30", "SCGMgmtIp"="2.2.2.2"
Accounting Server [{accSrvrIp}] not reachable from Radius Proxy [{radProxyIp}] on
{produce.short.name} [{SCGMgmtIp}]
This alarm is triggered when the accounting server cannot be reached.
Manual intervention is required. Check the web interface for the connection to the
AAA interface. Also, check if the RADIUS server can reach the AAA server
interface.
Accounting failed over to secondary
accFailedOverToSecondary
1653
Major
An alarm is raised for every event from the event code 1653. A single event
triggers a single alarm.
"mvnoId"=12 "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="radiusd"
"realm"= "wlan.mnc080.mcc405.3gppnetwork.org" "radProxyIp"="7.7.7.7"
"primary"="20.20.20.20" "secondary"="30.30.30.30"
Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on
Radius Proxy [7.7.7.7] on SCG[2.2.2.2]
This alarm is triggered when the secondary accounting RADIUS server is available
after the primary server becomes zombie or dead.
No action is required.
Accounting fallback to primary
accFallbackToPrimary
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide