IPMI Alarms
NOTE
This section is not applicable for vSZ-H.
Following are the alarms related to IPMIs.
•
ipmiVoltage
on page 108
•
ipmiThempBB
on page 109
•
ipmiThempFP
on page 109
•
ipmiThempIOH
on page 110
•
ipmiThempMemP
•
ipmiThempPS
on page 111
•
ipmiThempP
on page 111
•
ipmiThempHSBP
•
ipmiFan
on page 112
•
ipmiPower
on page 112
•
ipmiCurrent
on page 113
•
ipmiFanStatus
on page 113
•
ipmiPsStatus
on page 113
•
ipmiDrvStatus
on page 114
The controller has redundant six-fan cooling with four 80x38mm fans and two 60x38mm fans. There are four main cooling zones, as shown
in
Figure
3:
•
Zone 1 contains fans 0 and 1, which cool CPU1 and all the components in this zone.
•
Zone 2 contains fans 2 and 3, which cool CPU2, low-profile PCI cards, and all the other components in this zone.
•
Zone 3 contains fans 4 and 5, which cool full-height/length PCI cards and all the other components in this area.
•
Zone 4 is cooled by the power supply fans. This zone contains the SAS RAID and SAS/SATA boards. Cooling redundancy in this
zone is only achieved when there are two power supplies installed.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
on page 110
on page 111
Alarm Types
IPMI Alarms
107
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?