TABLE 337 Session deleted at DP event (continued)
Event
Description

Session delete at DP failed

TABLE 338 Session delete at DP failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

C2d configuration failed

TABLE 339 C2d configuration failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
NOTE
Refer to
Control and Data Plane Interface

Client Events

All client events from the AP will be appended with tenant ID ("tenantUUID":"xxxxx"). Following are the events related to clients.
Client authentication failed
Client joined
on page 205
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Session deleted at DP
This event occurs when the session deletes request (C-D-SESS-DEL-REQ) is
successfully acknowledged.
Session delete at DP failed
sessDeleteErrAtDblade
1208
Debug
"mvnoId"="12", "wlanId"="1", "zoneId"="10", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="aut", "realm"="realm sent by UE", "ctrlBladeIp"="1.1.1.1",
"dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
"ueMacAddr"="aa:bb:cc:gg:hh:ii", "ueImsi"="12345", "ueMsisdn"="98787"
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has failed
to delete from Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
This event occurs when the session delete request (C-D-SESS-DEL-REQ) results
in a timeout or a failed response.
C2d configuration failed
c2dCfgFailed
1209
Warning
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="aut", "realm"="NA"
"ctrlBladeIp"="1.1.1.1", "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
"cause"="<what was configured>"
Configuration [{cause}] from Control plane [{ctrlBladeIp}] failed to apply on Data
plane [{dataBladeIp}] at {produce.short.name} [{SCGMgmtIp}]
This event occurs when the configuration request (C-D-CFG-REQ) results in a
timeout or a failed response.
on page 200.
on page 205
Events Types

Client Events

203

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF