TABLE 74 Data plane core dead alarm (continued)
Alarm
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Data plane process restarted
TABLE 75 Data plane process restarted alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Data plane license is not enough
NOTE
Alarm 538 is applicable only for vSZ-H.
TABLE 76 Data plane license is not enough alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Data plane core dead
519
Critical
From the event code 519 an alarm is raised for every event. A single event
triggers a single alarm.
dpKey="xx:xx:xx:xx:xx:xx"
Data plane [{dpName||dpKey}] has dead data core.
This alarm is triggered when one or multiple data core packet pool is lost /dead.
No action required.
Data plane process restarted
dpProcessRestart
520
Major
From the event code 520 an alarm is raised for every event. A single event
triggers a single alarm.
dpKey="xx:xx:xx:xx:xx:xx", processName="xxxx"
[{processName}] process got re-started on data plane [{dpName&&dpKey}]
This alarm is triggered when any process on data plane crashes and restarts.
No action required.
Data plane license is not enough
dpLicenseInsufficient
538
Major
From the event code 538 an alarm is raised for every event. A single event
triggers a single alarm.
"count"=<delete-vdp-count>
DP license is not enough, [{count}] instance of DP will be deleted.
This alarm is triggered when the number of data plane licenses are insufficient.
Check if the number of data plane licenses has exceeded the limit. You would
need to purchase additional licenses, in case of insufficient licenses and
synchronize the licenses.
Alarm Types
Data Plane Alarms
93
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?
Questions and answers