Ap Failed To Connect To Ls; Ap State Change Alarms - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

TABLE 25 LS authentication failure alarm (continued)
Alarm
Severity
Aggregation Policy
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions

AP failed to connect to LS

TABLE 26 AP failed to connect to LS alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions
NOTE
Refer to
AP LBS Events

AP State Change Alarms

Following are the alarms related to access point state changes.
AP rebooted by system
AP disconnected
AP deleted
on page 70
AP cable modem interface down
AP DHCP service failure
AP NAT failure
on page 72
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
LS authentication failure
Major
From the event code 702 an alarm is raised for every event. A single event
triggers a single alarm.
"apMac"="xx:xx:xx:xx:xx:xx", "url"="","port"=""
AP [{apName&&apMac}] LBS authentication failed: url=[{url}], port=[{port}]
This alarm is triggered due to the authentication failure on connecting to the
location based service.
The password needs to be corrected in the LBS service page.
AP failed to connect to LS
apLBSConnectFailed
704
Major
From the event code 704 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm is auto cleared with the event code 703.
"apMac"="xx:xx:xx:xx:xx:xx", "url"="","port"=""
AP [{apName&&apMac}] connection failed to LS: url=[{url}], port=[{port}]
This alarm is triggered when the AP fails to connect to the location based service.
This alarm is triggered either when the location server is unreachable or the
network connection is unstable or the Domain Named System (DNS)
configuration is incorrect. It is recommended to check all the three possible error
codes - 701, 702 and 704.
on page 162.
on page 70
on page 70
on page 71
on page 71
Alarm Types

AP State Change Alarms

69

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF