Resource Unavailable; Hip Failed Over - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Alarm Types
System Alarms
TABLE 145 Keepalive failure alarm (continued)
Alarm
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions

Resource unavailable

TABLE 146 Resource unavailable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions

HIP failed over

NOTE
This alarm is not applicable for vSZ-H.
TABLE 147 HIP failed over alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
128
Keepalive failure
Major
From the event code 1003 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="nc",
"realm"="NA", "processName"="aut", "SCGMgmtIp"="2.2.2.2"
[{srcProcess}] on {produce.short.name} [{SCGMgmtIp}] restarted
[{processName}] process
This alarm is triggered when the mon/nc restarts the process due to a keep alive
failure.
Download the process log file from the controller web interface to locate the
cause of the error.
Resource unavailable
resourceUnavailable
1006
Critical
From the event code 1006 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="radiusd",
"realm"="NA", "SCGMgmtIp"="3.3.3.3', "cause"="xx"
System resource [{cause}] not available in [{srcProcess}] process at
{produce.short.name} [{SCGMgmtIp}]
This alarm is generated due to unavailability of any other system resource, such
as memcached.
A manual intervention is required. Check the memcached process. Also check if
the br1 interface is running.
HIP failed over
hipFailover
1016
Major
Alarm is raised for every event from event code 1016. A single event triggers a
single alarm.
"ctrlBladeMac"="50:A7:33:24:E7:90", "srcProcess"="HIP",
"realm"="NA", "processName"="HIP", "SCGMgmtIp"="100.13.0.102"
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide