Events Types

Control and Data Plane Interface

TABLE 330 CoA NAK received NAS event (continued)
Event
Severity
Attribute
Displayed on the web
interface
Description

CoA authorize only access reject

TABLE 331 CoA authorize only access reject event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

CoA RWSG MWSG notification failure

TABLE 332 CoA RWSG MWSG notification failure event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Control and Data Plane Interface

NOTE
This event is not applicable for vSZ-H.
200
CoA NAK received NAS
Debug
"mvnoId"="12" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="radiusd"
"userName"="abc@xyz.com" "radSrvrIp"="1.1.1.1" "nasIp"="3.3.3.3"
"SCGMgmtIp"="2.2.2.2"
CoA NAK received from NAS(AP) for forwarded/proxied CoA [{radSrvrIp}]
This event occurs when a change of authorization, not acknowledged is received
from the NAS server.
CoA authorize only access reject
coaAuthorizeOnlyAccessReject
1649
Critical
"mvnoId"="12" "wlanId"="1","zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="radiusd" "realm"="wlan.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" "aaaSrvrIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345","ueMsisdn"="98787","rmtRadSrvrIp"="40.40.40.40"
CoA Authorize Only unsuccessful for AAA Server [rmtRadSrvrIp] for UE
[ueMacAddr]
This event occurs when the change of authorization is rejected.
CoA RWSG MWSG notification failure
coaRWSGMWSGNotifFailure
1650
Major
mvnoId"=12 "wlanId"=1 "zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="radiusd" "userName"=abc@xyz.com
"realm"="wlan.mnc080.mcc405.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"apType" = " "ueMacAddr"="aa:bb:cc:gg:hh:ii"
Session Modify MWSG-RWSG Notification Failure/No response received
This event occurs when the change of authorization in RADIUS /metro wireless
service gateway notification fails.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF