Produce.short.name} Failed To Connect To Ls; Syslog Server Unreachable - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

TABLE 137 LS authentication failure alarm (continued)
Alarm
Aggregation Policy
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions

{produce.short.name} failed to connect to LS

TABLE 138 {produce.short.name} failed to connect to LS alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions

Syslog server unreachable

TABLE 139 Syslog server unreachable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
LS authentication failure
From the event code 722 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="xx:xx:xx:xx:xx:xx", "url"="", "port"="", "SCGMgmtIp"=""
{produce.short.name} [{SCGMgmtIp}] authentication failed: url=[{url}],
port=[{port}]
This alarm is triggered due to the authentication failure on connecting to the
location based service.
Check the location server password.
{produce.short.name} failed to connect to LS
scgLBSConnectFailed
724
Major
From the event code 724 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm is auto cleared with the event code 723.
"ctrlBladeMac"="xx:xx:xx:xx:xx:xx", "url"="", "port"="", "SCGMgmtIp"=""
{produce.short.name} [{SCGMgmtIp}] connection failed to LS: url=[{url}],
port=[{port}]
This alarm is triggered when the controller fails to connect to the location based
service.
Check the location service configuration. Also check the network connectivity
between the controller and location server.
Syslog server unreachable
syslogServerUnreachable
751
Major
From the event code 751 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm is auto cleared with the event code 750.
"nodeMac"="xx:xx:xx:xx:xx:xx", "syslogServerAddress"="xxx.xxx.xxxx.xxx"
Syslog server [{syslogServerAddress}] is unreachable on {produce.short.name}.
This alarm is triggered when the syslog server is unreachable.
Check the network between the controller and the syslog server.
Alarm Types
System Alarms
125

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF