TABLE 5 Accounting fallback to primary alarm (continued)
Alarm
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
AP accounting message mandatory parameter missing
NOTE
This alarm is not applicable for vSZ-H.
TABLE 6 AP accounting message mandatory parameter missing alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Action
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Accounting fallback to primary
1654
Major
An alarm is raised for every event from the event code 1654. A single event
triggers a single alarm.
"mvnoId"=12 "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="radiusd"
"realm"= "wlan.mnc080.mcc405.3gppnetwork.org" "radProxyIp"="7.7.7.7"
"primary"="20.20.20.20" "secondary"="30.30.30.30"
Radius Server Fallback to Primary [{primary}] from Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
This alarm is triggered when the automatic fallback is enabled. The accounting
failover to secondary server has occurred, the revival timer for primary server has
expired and the requests falls back to the primary server.
No action is required.
AP accounting message mandatory parameter missing
apAcctMsgMandatoryPrmMissing
1901
Critical
From the event code 1901 an alarm is raised for every event. A single event
triggers a single alarm.
"mvnoId"="12","wlanId"=1, "zoneId"="10", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="aut",
"realm"="wlan.3gppnetwork.org","SCGMgmtIp"="2.2.2.2",
"ueMacAddr"="aa:bb:cc:gg:hh:ii","ueImsi"="12345",
"ueMsisdn"="98787"
[{srcProcess}] Mandatory attribute missing in Accounting Packet received from
AP [{apIpAddress}] on {produce.short.name} [{SCGMgmtIp}], with username
[{ueImsi}@{realm}]
This alarm is triggered when the controller fails to the find the mandatory
parameter in the RADIUS accounting message received from the AP. This
mandatory parameter is required for generating the WAN-CDR.
Download the RADIUS log file from the web interface to check the error cause.