Events Types
Data Plane Events

Data plane fails to connect to the other data plane

NOTE
Events 1257 to 1267 are not applicable to SCG.
TABLE 488 Data plane fails to connect to the other data plane event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Auto Clearance
NOTE
Events 1257 to 1267 are not applicable to SCG.

Data plane disconnects to the other data plane

NOTE
Events 1257 to 1267 are not applicable to SCG.
TABLE 489 Data plane disconnects to the other data plane event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Start CALEA mirroring client in data plane

NOTE
Events 1257 to 1267 are not applicable to SCG.
TABLE 490 Start CALEA mirroring client in data plane event
Event
Event Type
Event Code
Severity
254
Data plane fails to connect to the other data plane
dpP2PTunnelConnectFail
1261
Warning
"dpKey"="xx:xx:xx:xx:xx:xx", "dpIP"="xx.xx.xx.xx",
"targetDpKey"="xx:xx:xx:xx:xx:xx", "targetDpIp"="xxx.xxx.xxx.xxx"
Data Plane[{dpName&&dpKey}] fails connects to the other Data
Plane[{targetDpKey&&targetDpIp}]
This event occurs when the data plane fails to connect to another data plane.
This event triggers the alarm 1261, which is auto cleared by the event code 1260.
Data plane disconnects to the other data plane
dpP2PTunnelDisconnected
1262
Major
"dpKey"="xx:xx:xx:xx:xx:xx", "dpIP"="xx.xx.xx.xx",
"targetDpKey"="xx:xx:xx:xx:xx:xx","targetDpIp"="xxx.xxx.xxx.xxx"
Data Plane[{dpName&&dpKey}] disconnects to the other Data
Plane[{targetDpKey&&targetDpIp}]
This event occurs when the data plane disconnects from another data plane.
Start CALEA mirroring client in data plane
dpStartMirroringClient
1263
Informational
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide