Data plane disconnected
TABLE 69 Data plane disconnected alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions
Data plane physical interface down
TABLE 70 Data plane physical interface down alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions
Data plane rebooted
TABLE 71 Data plane rebooted alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Data plane disconnected
dpDisconnected
503
Critical
From the event code 513 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 512.
"dpKey"="xx:xx:xx:xx:xx:xx", "wsgIP"="xxx.xxx.xxx.xxx"
Data plane [{dpName||dpKey}] disconnected from {produce.short.name}
[{cpName||wsgIP}]
This alarm is triggered when the data plane gets disconnected from the controller
since it fails to update its status to the control plane.
Check if the communicator is still alive and if the cluster interface is working.
Data plane physical interface down
dpPhyInterfaceDown
504
Critical
From the event code 514 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 515.
"portID"="xx", "dpKey"="xx:xx:xx:xx:xx:xx"
Network link of port [{portID}] on data plane [{dpName||dpKey}] is down
This alarm is triggered when the physical interface link of the data plane is down
due to the fiber cable connection.
Check if the fiber cable between the data plane and the switch is firmly
connected.
Data plane rebooted
dpReboot
510
Minor
From the event code 506 an alarm is raised for every event. A single event
triggers a single alarm.
"dpKey"="xx:xx:xx:xx:xx:xx",