Authentication Fallback To Primary; Ad/Ldap Connected Successfully; Ad/Ldap Connectivity Failure - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Events Types
Authentication Events

Authentication fallback to primary

TABLE 314 Authentication fallback to primary event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

AD/LDAP connected successfully

TABLE 315 AD/LDAP connected successfully event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

AD/LDAP connectivity failure

TABLE 316 AD/LDAP connectivity failure event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
194
Authentication fallback to primary
authFallbackToPrimary
1652
Major
"mvnoId"=12 "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="radiusd"
"realm"= "wlan.mnc080.mcc405.3gppnetwork.org" "radProxyIp"="7.7.7.7"
"primary"="20.20.20.20" "secondary"="30.30.30.30" "SCGMgmtIp"="2.2.2.2"
Radius Server Fallback to Primary [{primary}] from Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
This event occurs when the automatic fallback is enabled. The authentication
failover to secondary server has occurred, the revival timer for primary server has
expired and the requests falls back to the primary server.
AD/LDAP connected successfully
racADLDAPSuccess
1751
Debug
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "mvnoId"=12, "srcProcess"="RAC",
"authSrvrIp"= "1.1.1.1"
"SCGMgmtIp"="2.2.2.2", "desc"="Successful connection to AD/LDAP"
[{srcProcess}] Connect to AD/LDAP[{authSrvrIp}] successfully from
SCG[{SCGMgmtIp}]
This event occurs when RADIUS connection to AD/LDAP server is successful.
AD/LDAP connectivity failure
racADLDAPFail
1752
Major
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "mvnoId"=12, "srcProcess"="RAC",
"authSrvrIp"="1.1.1.1", "SCGMgmtIp"="2.2.2.2"
"desc"= "Connection to AD/LDAP fails"
[{srcProcess}] Connect to AD/LDAP[{authSrvrIp}] fails from SCG[{SCGMgmtIp}]
This event occurs when RADIUS fails to connect to AD/LDAP server.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF