Association Establishment Failed; Association Down - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

TABLE 99 App server inactive alarm (continued)
Alarm
Displayed on the web
interface
Description
Recommended Actions

Association establishment failed

TABLE 100 Association establishment failed alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions

Association down

TABLE 101 Association down alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
App server inactive
"pointCode"="1.1.1", "SSN" = "7"
Application Server Inactive, Routing Context [{routingContext}], lpcal Point Code
[{pointCode}], local SSN [{SSN}]
This alarm is triggered when the local application server is inactive due to
application service provider inactive (ASP_INACTIVE) or application service
provider inactive acknowledgment (ASP_INACTIVE_ACK) from remote IP security
protocol (IPSP) or signalling gateway (SG).
Manual intervention is required.
Association establishment failed
assocEstbFailed
1626
Critical
From the event code 1626 an alarm is raised for every five events or events
occurring within a span of 2 minutes.
The alarm code is auto cleared with the event code 1628.
"mvnoId"="3", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="hip", "srcIP"="10.1.4.10", "srcPort"="2960",
"destIP"="10.1.4.20", "destPort"="2960"
Unable to establish SCTP association. srcIP [{srcIP}], srcPort [{srcPort}],
destIP[{destIP}], destPort [{destPort}]
This alarm is triggered when it is unable to establish an association to the IP
security protocol (IPSP) or signalling gateway (SG).
Manual intervention is required.
Association down
assocDown
1627
Critical
From the event code 1627 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 1628.
"mvnoId"="3", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="hip",
"srcIP"="10.1.4.10", "srcPort"="2960",
"destIP"="10.1.4.20", "destPort"="2960"
SCTP association DOWN. srcIP [{srcIP}], srcPort [{srcPort}], destIP[{destIP}],
destPort [{destPort}]
Alarm Types
GR Interface Alarms
105

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF