Session Update At Dp Failed; Session Deleted At Dp - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Events Types
Control and Data Plane Interface
TABLE 335 Session updated at DP event (continued)
Event
Severity
Attribute
Displayed on the web
interface
Description

Session update at DP failed

TABLE 336 Session update at DP failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Session deleted at DP

TABLE 337 Session deleted at DP event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
202
Session updated at DP
Debug
"mvnoId"="12", "wlanId"="1", "zoneId"="10", "srcProcess"="aut",
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "realm"="realm sent by UE",
"ctrlBladeIp"="1.1.1.1", "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
"ueMacAddr"="aa:bb:cc:gg:hh:ii",
"ueImsi"="12345", "ueMsisdn"="98787"
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has been
updated at Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
This event occurs when the session updates the request (C-D-SESS-UPD-REQ)
successfully.
Session update at DP failed
sessUpdateErrAtDblade
1206
Debug
"mvnoId"="12", "wlanId"="1", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="aut", "zoneId"="10", "realm"="realm sent by UE",
"ctrlBladeIp"="1.1.1.1", "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
"ueMacAddr"="aa:bb:cc:gg:hh:ii",
"ueImsi"="12345", "ueMsisdn"="98787"
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has failed
to update at Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
This event occurs when the session update request fails (C-D-SESS-UPD-REQ).
This is either due to a request timeout or a failed response.
Session deleted at DP
sessDeletedAtDblade
1207
Debug
"mvnoId"="12","wlanId"="1""zoneId"="10", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="aut", "realm"="realm sent by UE", "ctrlBladeIp"="1.1.1.1",
"dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2",
"ueMacAddr"="aa:bb:cc:gg:hh:ii", "ueImsi"="12345", "ueMsisdn"="98787"
TTG/PDG session for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] has been
deleted from Data plane [{dataBladeIp}] by Control plane [{ctrlBladeIp}] at
{produce.short.name} [{SCGMgmtIp}]
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF