Cluster Upload Ap Firmware Failed; Cluster Add Ap Firmware Failed; Unsync Ntp Time - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Cluster upload AP firmware failed

TABLE 57 Cluster upload AP firmware failed alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions

Cluster add AP firmware failed

TABLE 58 Cluster add AP firmware failed alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions

Unsync NTP time

TABLE 59 Unsync NTP time alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Cluster upload AP firmware failed
clusterUploadAPFirmwareFailed
850
Major
From the event code 850 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 849
"clusterName"="xx"
Cluster [{clusterName}] upload AP firmware failed.
This alarm is triggered when the cluster upload to AP firmware fails.
It is recommended that the operator uploads the AP patch.
Cluster add AP firmware failed
clusterAddAPFirmwareFailed
853
Major
From the event code 853 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 852
"clusterName"="xx"
Cluster [{clusterName}] add AP firmware failed.
This alarm is triggered when the cluster upload to AP firmware fails.
It is recommended that the operator applies the AP patch.
Unsync NTP time
unsyncNTPTime
855
Major
From the event code 855 an alarm is raised for every event. A single event
triggers a single alarm.
"nodeName"="xx", "reason"="xx", "status"="xx"
Node [{nodeName}] time is not synchronized because of [{reason}]. The time
difference is [{status}] seconds.
This alarm is triggered when the cluster time is not synchronized.
Alarm Types
Cluster Alarms
85

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF