Events Types
System Events
TABLE 679 ZD AP migrated event (continued)
Event
Attribute
Displayed on the web
interface
Description

ZD AP rejected

TABLE 680 ZD AP rejected event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

ZD AP migration failed

TABLE 681 ZD AP migration failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Database error

TABLE 682 Database error event
Event
Event Type
Event Code
Severity
Attribute
324
ZD AP migrated
"apMac"=" C0:C5:20:12:2B:2C ", "serialNumber"="501003003033",
"model"="R700", "firmware"="3.2.0.0.x"
ZD-AP [{apMac}] / [{serialNumber}] model [{model}] has been upgraded with
{produce.short.name} AP firmware version - [{firmware}]
This event occurs when a ZoneDirector AP has upgraded its firmware with the
controller AP firmware image.
ZD AP rejected
zdAPRejected
2003
Warning
"apMac"=" C0:C5:20:12:2B:2C ", "serialNumber"="501003003033",
"model"="ZF7962"
ZD-AP [{apMac}] / [{serialNumber}] model [{model}] is not being upgraded with
{produce.short.name} AP firmware because of ACL setting.
This event occurs when the ZoneDirector AP is not upgraded with the controller
AP firmware because of ACL setting.
ZD AP migration failed
zdAPMigrationFailed
2004
Major
"apMac"=" C0:C5:20:12:2B:2C ", "serialNumber"="501003003033",
"model"="ZF7962", "firmware"="3.0.0.0.0"
ZD-AP [{apMac}] / [{serialNumber}] model [{model}] is failed to upgrade with
{produce.short.name} AP firmware version - [{firmware}]
This event occurs when the Zone Director AP fails to upgrade with the controller
AP firmware image.
Database error
cassandraError
3001
Major
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "SCGMgmtIp"="2.2.2.2", reason="reason",
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF