Disk usage threshold exceeded
•
CPU threshold back to normal
•
Memory threshold back to normal
•
Disk threshold back to normal
•
License threshold exceeded
•
Rate limit threshold surpassed
•
Rate limit threshold restored
•
Rate limit for TOR surpassed
•
The number of users exceed its limit
•
The number of devices exceeded its limit
CPU threshold exceeded
TABLE 688 CPU threshold exceeded event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Auto Clearance
Memory threshold exceeded
TABLE 689 Memory threshold exceeded event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Auto Clearance
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
on page 328
on page 328
on page 328
on page 328
on page 329
on page 329
on page 330
on page 330
on page 330
on page 331
CPU threshold exceeded
cpuThresholdExceeded
950
Critical
"nodeName"="xxx", "nodeMac"="xx:xx:xx:xx:xx:xx", "perc"="XX"
CPU threshold [{perc}%] exceeded on control plane [{nodeName}-C]
This event occurs when the CPU usage exceeds the threshold limit of 80%.
This event triggers the alarm 950, which is auto cleared by the event code 954.
Memory threshold exceeded
memoryThresholdExceeded
951
Critical
"nodeName"="xxx","nodeMac"="xx:xx:xx:xx:xx:xx", "perc"="XX"
Memory threshold [{perc}%] exceeded on control plane [{nodeName}-C].
This event occurs when the memory usage exceeds the threshold limit of 85%
and for vSZ-H the limit is 90%.
This event triggers the alarm 951, which is auto cleared by the event code 954.
Events Types
Threshold Events
327
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?
Questions and answers