Alarm Types
System Alarms

CSV export FTP maximum retry

TABLE 140 CSV export FTP maximum retry alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the
SmartZone web interface
Description

CSV export disk threshold exceeded

TABLE 141 CSV export disk threshold exceeded alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions

CSV export disk max capacity reached

TABLE 142 CSV export disk max capacity reached alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the
SmartZone web interface
Description
126
CSV export FTP maximum retry
csvFtpTransferMaxRetryReached
974
Major
From the event code 974 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm is auto cleared with the event code 750.
"nodeName"="xx:xx:xx:xx:xx:xx", "ip"="xx:xx:xx:xx:xx:xx",
"portID"="xx:xx:xx:xx:xx:xx", "filename"="xxx.xxx.xxxx.xxx"
This alarm is triggered when CSV file fails to transfer after a maximum of five (5)
retries.
CSV export disk threshold exceeded
csvDiskThresholdExceeded
975
Warning
From the event code 975 an alarm is raised for every event. A single event
triggers a single alarm.
"nodeName"="xx:xx:xx:xx:xx:xx", "threshold"="xx:xx:xx:xx:xx:xx",
"availableDiskSize"="xx:xx:xx:xx:xx:xx"
This alarm is triggered when CSV report size exceeds 80% of its capacity.
CSV export disk max capacity reached
csvDiskMaxCapacityReached
976
Critical
From the event code 976 an alarm is raised for every event. A single event
triggers a single alarm.
"nodeName"="xx:xx:xx:xx:xx:xx", "allocatedDiskSize"="xx:xx:xx:xx:xx:xx"
This alarm is triggered when CSV report size reaches its maximum capacity.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF