Process Restart; Service Unavailable; Keepalive Failure - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

TABLE 142 CSV export disk max capacity reached alarm (continued)
Alarm
Recommended Actions

Process restart

TABLE 143 Process restart alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions

Service unavailable

TABLE 144 Service unavailable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions

Keepalive failure

TABLE 145 Keepalive failure alarm
Alarm
Alarm Type
Alarm Code
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
CSV export disk max capacity reached
Process restart
processRestart
1001
Major
From the event code 1001 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="nc",
"realm"="NA", "processName"="aut", "SCGMgmtIp"="2.2.2.2"
[{processName}] process got re-started on {produce.short.name} [{SCGMgmtIp}]
This alarm is triggered when any process crashes and restarts.
Download the process log file from the controller web interface to understand the
cause of the error.
Service unavailable
serviceUnavailable
1002
Critical
From the event code 1002 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="nc",
"realm"="NA", "processName"="aut", "SCGMgmtIp"="2.2.2.2"
[{processName}] process is not stable on {produce.short.name} [{SCGMgmtIp}]
This alarm is triggered when the process repeatedly restarts and is unstable.
A manual intervention is required. Download the process log file from the
controller web interface to find the cause of the error.
Keepalive failure
keepAliveFailure
1003
Alarm Types
System Alarms
127

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents