Delete Bearer Request Failed; Update Bearer Request Failed - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Alarm Types
Gn/S2a Interface Alarms
TABLE 93 Delete session response failed alarm (continued)
Alarm
Attribute
Displayed on the web
interface
Description
Recommended Actions

Delete bearer request failed

TABLE 94 Delete bearer request failed alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions

Update bearer request failed

TABLE 95 Update bearer request failed alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
102
Delete session response failed
"mvnoId"="12" "wlanId"="1" "zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"= "wlan.mnc080.mcc405.3gppnetwork.org"
"gtpcIp"="5.5.5.5" "pgwIp"="1.1.1.1" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345" "ueMsisdn"="98787"
"apn"="ruckus.com" "cause"="<reason for failure>"
[{srcProcess}] Delete Session response from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
Delete session response from PDN GW fails due to the specified cause.
Download the SM log to check the cause of the error.
Delete bearer request failed
deleteBearerRequestFailed
1958
Major
From the event code 1958 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut" "realm"= "NA"
"gtpcIp"="5.5.5.5" "pgwIp"="1.1.1.1" "SCGMgmtIp"="2.2.2.2" "cause"="<reason
for failure>"
[{srcProcess}] Delete Bearer Request from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
This alarm is triggered when the delete bearer request from PDN GW fails.
Download the SM log to check the cause of the error.
Update bearer request failed
updateBearerRequestFailed
1959
Major
From the event code 1959 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut" "realm"= "NA"
"gtpcIp"="5.5.5.5" "pgwIp"="1.1.1.1" "SCGMgmtIp"="2.2.2.2" "cause"="<reason
for failure>"
[{srcProcess}] Update bearer request from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
Update bearer request failed, decode failed.
Download the SM log to check the cause of the error.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF