Configuration Update Failed; Configuration Receive Failed; Incorrect Flat File Configuration - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Configuration update failed

TABLE 449 Configuration update failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Configuration receive failed

TABLE 450 Configuration receive failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Incorrect flat file configuration

TABLE 451 Incorrect flat file configuration event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Configuration update failed
cfgUpdFailed
1008
Debug
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" , "srcProcess"="cnr" "realm"="NA"
"processName"="aut" "SCGMgmtIp"="x.x.x.x" "cause"="xx"
Failed to apply configuration [{cause}] in [{processName}] process at
{produce.short.name} [{SCGMgmtIp}].
This event occurs when the CNR receives a negative acknowledgment when
applying the configuration settings to the module. Possible cause is that a
particular process/module is down.
Configuration receive failed
cfgRcvFailed
1009
Debug
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="cnr" "realm"="NA"
"SCGMgmtIp"="x.x.x.x", "cause"="xx"
Failed to fetch configuration [{cause}] by CNR in {produce.short.name}
[{SCGMgmtIp}].
This event occurs when the CNR receives an error or negative acknowledgment/
improper/incomplete information from the configuration change notifier (CCN).
Incorrect flat file configuration
incorrectFlatFileCfg
1012
Major
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut", "realm"="NA",
"SCGMgmtIp"="xxxx", "cause"="xxx", "file"="xx"
[{srcProcess}] detected an configuration parameter is incorrectly configured in file
[{file}] at {produce.short.name} [{SCGMgmtIp}].
This event occurs when any flat file configuration parameter is not semantically or
syntactically correct.
Events Types
Configuration Events
241

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF