Wds Device Joined; Wds Device Left; Client Is Blocked Because Of Barring Ue Rule - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Events Types
Client Events
TABLE 364 Force DHCP disconnected event (continued)
Event
Description

WDS device joined

TABLE 365 WDS device joined event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

WDS device left

TABLE 366 WDS device left event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Client is blocked because of barring UE rule

TABLE 367 Client is blocked because of barring UE rule event
Event
Event Type
Event Code
Severity
Attr ibute
Displayed on the web
interface
Description
214
Force DHCP disconnected
This event occurs when the client disconnects by force from the dynamic host
configuration protocol.
WDS device joined
wdsDeviceJoin
226
Informational
"apName"="xxxxx", "apMac"="xx:xx:xx:xx:xx:xx", "clientMac"="xx:xx:xx:xx:xx:xx",
"wdsDevicetMac"="xx:xx:xx:xx:xx:xx"
Device [{wdsDeviceMac}] sends traffic via Client [{clientMac}] in AP
[{apName&&apMac}].
This event occurs when a subscriber device joins the network provided by a
Customer-Premises Equipment (CPE) of a client associated AP through a wireless
distribution system (WDS) mode.
WDS device left
wdsDeviceLeave
227
Informational
"apName"="xxxxx", "apMac"="xx:xx:xx:xx:xx:xx", "clientMac"="xx:xx:xx:xx:xx:xx",
"wdsDevicetMac"="xx:xx:xx:xx:xx:xx"
Device [{wdsDeviceMac}] stops traffic via Client [{clientMac}] in AP
[{apName&&apMac}].
This event occurs when a subscriber device leaves the network provided by a
CPE client associated to an AP through WDS.
Client is blocked because of barring UE rule
clientBlockByBarringUERule
228
Informational
"apMac"="xx:xx:xx:xx:xx:xx", "clientMac"="xx:xx:xx:xx:xx:xx"
Client [clientMac}] of WLAN [{ssid}] from AP [{apName&&apMac}] was blocked
because of barring UE rule.
This event occurs when a client is temporally blocked by the UE barring rule.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF