Events Types
Gn/S2a Interface Events

Unknown UE

TABLE 519 Unknown UE event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

PDP update success COA

TABLE 520 PDP update success COA event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

PDP update fail COA

TABLE 521 PDP update fail COA event
Event
Event Type
Event Code
Severity
Attribute
266
Unknown UE
unknownUE
1231
Minor
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut" "realm"="wlan.
3gppnetwork.org" "ueMacAddr"="bb:aa:dd:dd:ee:ff" "cause"="Subscriber Info
Not Found" "SCGMgmtIp"="2.2.2.2"
Received request from un-known UE [{ueMacAddr}] in {produce.short.name}
[{SCGMgmtIp}]
This event occurs when TTG control plane receives either a DHCP message or a
trigger from data plane. It is unable to find the user equipment in the session
context.
PDP update success COA
pdpUpdSuccCOA
1244
Debug
"mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"aaaSrvrIp"="5.5.5.5"
PDP context updated for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at
{produce.short.name} [{SCGMgmtIp}] because of COA from AAA server
[{aaaSrvrIp}]
This event occurs when the packet data protocol update is successful when
initiating the update process based on the change of authorization received from
the external AAA server.
PDP update fail COA
pdpUpdFailCOA
1245
Debug
"mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"aaaSrvrIp"="5.5.5.5" "cause"="cause of error"
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF