Alarm Types
AP Authentication Alarms
RADIUS server unreachable
TABLE 10 RADIUS server unreachable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Auto Clearance
Displayed on the web
interface
Description
Recommended Actions
LDAP server unreachable
TABLE 11 LDAP server unreachable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Auto Clearance
Displayed on the web
interface
Description
Recommended Actions
AD server unreachable
TABLE 12 AD server unreachable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
62
RADIUS server unreachable
radiusServerUnreachable
2102
Major
From the event code 2102 an alarm is raised for every event. A single event
triggers a single alarm.
"apMac="xx:xx:xx:xx:xx:xx","ip"="17.0.0.12","fwVersion"="3.2.0.0.x","model"="Z
F7982","zoneUUID"="f77a8816-3049-40cd-8484-82919275ddc3","zoneName"=
"Default Zone","apLocation"="".
The alarm is auto cleared with the event code 2101.
AP [{apName&&apMac}] is unable to reach radius server [{ip}].
This alarm is triggered when AP is unable to reach RADIUS server.
Check the network connectivity between AP and RADIUS server.
LDAP server unreachable
ldapServerUnreachable
2122
Major
From the event code 2122 an alarm is raised for every event. A single event
triggers a single alarm.
"apMac="xx:xx:xx:xx:xx:xx","ip"="17.0.0.12","fwVersion"="3.2.0.0.x","model"="Z
F7982","zoneUUID"="f77a8816-3049-40cd-8484-82919275ddc3","zoneName"=
"Default Zone","apLocation"=""
The alarm is auto cleared with the event code 2121.
AP [{apName&&apMac}] is unable to reach LDAP server [{ip}].
This alarm is triggered when AP is unable to reach LDAP server.
Check the network connectivity between AP and LDAP server.
AD server unreachable
adServerUnreachable
2142
Major
From the event code 2142 an alarm is raised for every event. A single event
triggers a single alarm.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?
Questions and answers