Modify bearer response failed
TABLE 527 Modify bearer response failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Delete session response failed
TABLE 528 Delete session response failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Delete bearer request failed
TABLE 529 Delete bearer request failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Modify bearer response failed
modifyBearerResponseFailed
1956
Major
mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345" "ueMsisdn"="98787",
"APN"="ruckus.com" "cause"="xx","pgwIp"="1.1.1.1"
[{srcProcess}] Modify Bearer Response from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
This event occurs when modify bearer response from PDN GW fails with a cause.
Delete session response failed
deleteSessionResponseFailed
1957
Major
mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345" "ueMsisdn"="98787"
"APN"="ruckus.com" "cause"="xx","pgwIp"="1.1.1.1"
[{srcProcess}] Delete Session response from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
This event occurs when the delete session response from PDN GW fails.
Delete bearer request failed
deleteBearerRequestFailed
1958
Major
mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345" "ueMsisdn"="98787"
"APN"="ruckus.com","cause"="<reason for failure>","pgwIp"="1.1.1.1"
[{srcProcess}] Delete Bearer Request from PDN GW with IP [{pgwIp}] on
{produce.short.name} [{SCGMgmtIp}] failed, for UE with username
[{ueImsi}@{realm}] because [{cause}]
This event occurs when the delete bearer request from PDN GW fails with decode
error.
Events Types
Gn/S2a Interface Events
269
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?