Ap Lbs Alarms; No Ls Responses; Ls Authentication Failure - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

Alarm Types

AP LBS Alarms

TABLE 23 AP join zone failed alarm (continued)
Alarm
Attribute
Displayed on the web
interface
Description
Recommended Actions
NOTE
Refer to
AP Communication Events

AP LBS Alarms

Following are the alarms related to AP Location Based Service (LBS).

No LS responses

LS authentication failure

AP failed to connect to LS
No LS responses
TABLE 24 No LS responses alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the
SmartZone web interface
Description
Recommended Actions
LS authentication failure
TABLE 25 LS authentication failure alarm
Alarm
Alarm Type
Alarm Code
68
AP join zone failed
"apMac"="xx:xx:xx:xx:xx:xx", "zoneUUID"="xx:xx:xx:xx:xx:xx",
"targetZoneUUID"="xx:xx:xx:xx:xx:xx", "reason"="xx:xx:xx:xx:xx:xx"
AP [{apName&&apMac}] failed to join to zone [{targetZoneName}]. Reason:
[{reason}]
This alarm is triggered when the AP fails to join the specified zone
Check if the number of RXGW (AP direct tunnel license) licenses has exceeded
the limit. You would need to purchase additional licenses, in case of insufficient
licenses.
on page 154.
on page 68
on page 68
on page 69
No LS responses
apLBSNoResponses
701
Major
From the event code 701 an alarm is raised for every event. A single event
triggers a single alarm.
"apMac"="xx:xx:xx:xx:xx:xx", "url"="","port"=""
AP [{apName&&apMac}] no response from LS: url=[{url}], port=[{port}]
This alarm is triggered when the AP does not get a response when trying to
connect to the location based service.
This alarm is triggered when the location server fails to respond to the AP request
due to an error or the server is a maintenance mode. Report this to the location
server owner.
LS authentication failure
apLBSAuthFailed
702
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF