Alarm Types
System Alarms
Process initiated
NOTE
This alarm is not applicable for vSZ-H.
TABLE 158 Process initiated alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
PMIPv6 unavailable
NOTE
This alarm is not applicable for vSZ-H.
TABLE 159 PMIPv6 unavailable alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Memory allocation failed
NOTE
This alarm is not applicable for vSZ-H.
TABLE 160 Memory allocation failed alarm
Alarm
Alarm Type
Alarm Code
134
Process initiated
processInit
5001
Major
From the event code 5001 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "SCGMgmtIp"="2.2.2.2"
PMIPv6 process got re-started on {produce.short.name} [{SCGMgmtIp}]
This alarm is logged when PMIPv6 process restarts.
A manual intervention is required. Download the PMIPv6d log file from the
controller to check the cause of error.
PMIPv6 unavailable
pmipUnavailable
5002
Critical
From the event code 5002 an alarm is raised for every event. A single event
triggers a single alarm.
"ctrlBfladeMac"="aa:bb:cc:dd:ee:ff", "SCGMgmtIp"="2.2.2.2"
PMIPv6 process is not stable on {produce.short.name} [{SCGMgmtIp}]
This alarm is logged when the PMIPv6 process repeatedly restarts and is not
stable.
Check the PMIPv6d application log and status from the controller web interface.
Memory allocation failed
unallocatedMemory
5003
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?
Questions and answers