TABLE 147 HIP failed over alarm (continued)
Alarm
Displayed on the web
interface
Description
Recommended Actions
Diameter initialization error
NOTE
This alarm is not applicable for vSZ-H.
TABLE 148 Diameter initialization error alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Diameter peer transport failure
NOTE
This alarm is not applicable for vSZ-H.
TABLE 149 Diameter peer transport failure alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
HIP failed over
[{srcProcess}] Node transitioned to Active on {produce.short.name}
[{SCGMgmtIp}]
This alarm is logged when the standby host identity protocol (HIP) transits to an
active node and is included in control plane identifier of the newly active HIP.
A manual intervention is required.
Diameter initialization error
diaInitilizeErr
1401
Critical
An alarm is raised for every 2events within a duration of 30 minutes.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="<Application Name>"
"realm"="ruckus.com" "originHost" = "Node1" "SCGMgmtIp"="2.2.2.2" "desc"
= "Diameter Stack Initialization Failure on {produce.short.name}"
[{srcProcess}] Diameter Stack Initialization Failure on {produce.short.name}
[{SCGMgmtIp}]
This alarm is triggered due to stack initialization failure.
Check the network interface settings and port settings. The port could be in use
by another application.
Diameter peer transport failure
diaPeerTransportFailure
1403
Major
A single event triggers a single alarm.
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "mvnoId"=12 "srcProcess"="<Application
Name>" "realm"="ruckus.com" "originHost" = "Node1" "SCGMgmtIp"="2.2.2.2"
"peerIp" = "3.3.3.3" "peerName" = "OCS1" "peerRealmName" =
"organization.com" "desc" = "Failed to read from peer socket"
[{srcProcess}] Failed to read from peer [{peerName}] Transport Realm
[{peerRealmName}] on {produce.short.name} [{SCGMgmtIp}]
This alarm is triggered when the diameter stack fails to read from the peer socket
and the peer transport is down.
Check if the transport is up for the peer. Peer application may not be running.
Alarm Types
System Alarms
129
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?