Fast Re-Authentication Failed; Authentication Failed Over To Secondary - Ruckus Wireless Virtual SmartZone High Scale Reference Manual

Alarm and event, supporting smartzone 3.6
Hide thumbs Also See for Virtual SmartZone High Scale:
Table of Contents

Advertisement

TABLE 311 Fast re-authentication succeeded event (continued)
Event
Displayed on the web
interface
Description

Fast re-authentication failed

NOTE
This event is not applicable for vSZ-H.
TABLE 312 Fast re-authentication failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description

Authentication failed over to secondary

TABLE 313 Authentication failed over to secondary event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Fast re-authentication succeeded
Fast re-auth ID based authentication successful for UE with IMSI [{ueImsi}] and
MSISDN [{ueMsisdn}]. {produce.short.name} used is [{SCGMgmtIp}]
This event occurs after resending RADIUS accept back to AP. This event is
applicable when, the {produce.short.name} acts as a hosted AAA server and for
TTG/PDG session.
Note: FastReauth ID is used for authentication.
Fast re-authentication failed
fastReauthFailed
1609
Debug
"mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"=" radiusd" "realm"="wlan.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345"
"ueMsisdn"="98787" "cause"="<Cause of failure>" "authType"="EAP-SIM/AKA"
Fast re-auth ID based authentication failed for UE with IMSI [{ueImsi}] and
MSISDN [{ueMsisdn}]. Cause = [{cause}]. {produce.short.name} used is
[{SCGMgmtIp}]
This event occurs when the RADIUS reject is sent back for fast reauthentication.
This event applies when the controller acts as a host AAA server. The MS-ISDN is
provided (if available).
Note: Attribute FastReuathID is used for reauthentication.
Authentication failed over to secondary
authFailedOverToSecondary
1651
Major
"mvnoId"=12 "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="radiusd"
"realm"= "wlan.mnc080.mcc405.3gppnetwork.org" "radProxyIp"="7.7.7.7"
"primary"="20.20.20.20" "secondary"="30.30.30.30" "SCGMgmtIp"="2.2.2.2"
Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
This event occurs when the secondary authentication RADIUS server is available
after the primary server becomes zombie or dead.
Events Types
Authentication Events
193

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF