Following are the events related to control and data plane events.
•
DP connected
on page 201
•
GtpManager (DP) disconnected
•
Session updated at DP
•
Session update at DP failed
•
Session deleted at DP
•
Session delete at DP failed
•
C2d configuration failed
DP connected
TABLE 333 DP connected event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
GtpManager (DP) disconnected
TABLE 334 GtpManager (DP) disconnected event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Auto Clearance
Session updated at DP
TABLE 335 Session updated at DP event
Event
Event Type
Event Code
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
on page 201
on page 201
on page 202
on page 202
on page 203
on page 203
DP connected
connectedToDblade
1201
Informational
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="aut", "realm"="NA",
"ctrlBladeIp"="1.1.1.1", "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2"
The connectivity between Control plane [{ctrlBladeIp}] and Data plane
[{dataBladeIp}] is established at {produce.short.name} [{SCGMgmtIp}]
This event occurs when control plane completes the configuration procedure
successfully.
GtpManager (DP) disconnected
lostCnxnToDblade
1202
Major
"ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="aut", "realm"="NA",
"ctrlBladeIp"="1.1.1.1", "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2"
The connectivity between Control plane [{ctrlBladeIp}] and Data plane
[{dataBladeIp}] is lost at {produce.short.name} [{SCGMgmtIp}]
This event occurs when either the transmission control protocol connection is lost
or when the control plane is unable to complete the configuration procedure.
This event triggers the alarm 1202, which is auto cleared by the event code 1201.
Session updated at DP
sessUpdatedAtDblade
1205