Node physical interface down

TABLE 52 Node physical interface down alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions

Cluster node rebooted

TABLE 53 Cluster node rebooted alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions

Cluster node shut down

TABLE 54 Cluster node shut down alarm
Alarm
Alarm Type
Alarm Code
Severity
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Node physical interface down
nodePhyInterfaceDown
810
Critical
From the event code 824 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 825.
"nodeName"="xxx", "nodeMac"=" xx:xx:xx:xx:xx:xx",
"ifName"="xxxx"
Physical network interface [{networkInterface||ifName}] on node [{nodeName}] is
down.
This alarm is triggered when the physical interface of a node is down.
Check if the network cables of both the physical interfaces are broken.
Alternatively, check if the physical interfaces for this bond interface are broken.
Please send the log files stored in the path -
/opt/ ruckuswireless/controller/log/system to Ruckus support for
analysis.
Cluster node rebooted
nodeRebooted
811
Major
From the event code 826 an alarm is raised for every event. A single event
triggers a single alarm.
"nodeName"="xxx", "nodeMac"="xxx"
Node [{nodeName}] in cluster [{clusterName}] rebooted
This alarm is triggered when the node is rebooted.
Usually, this occurs due to user actions like manual reboot of a node, upgrade or
restoration of a cluster. Please send the log files stored in the path - /opt/
ruckuswireless/controller/log/system to Ruckus support for
analysis.
Cluster node shut down
nodeShutdown
813
Major
Alarm Types
Cluster Alarms
83

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Smartzone 300Smartcell gateway 200

Table of Contents

Save PDF