Events Types
Accounting Events
Accounting session stopped successfully
NOTE
This event is not applicable for vSZ-H.
TABLE 176 Accounting session stopped successfully event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Accounting session stopped failed
NOTE
This event is not applicable for vSZ-H.
TABLE 177 Accounting session stopped failed event
Event
Event Type
Event Code
Severity
Attribute
Displayed on the web
interface
Description
Accounting session interim failed
NOTE
This event is not applicable for vSZ-H.
TABLE 178 Accounting session interim failed event
Event
Event Type
Event Code
Severity
144
Accounting session stopped successfully
accSessStopSucc
1246
Debug
"mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
Accounting session stopped for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}]
at {produce.short.name} [{SCGMgmtIp}].
This event occurs when the accounting session stops. This event is applicable for
TTG/PDG provided accounting process is enabled for the session.
Accounting session stopped failed
accSessStopFail
1247
Debug
"mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"cause"="<reason for failure>"
No Response received or Error Stopping accounting session for UE with IMSI
[{ueImsi}] and MSISDN [{ueMsisdn}] at {produce.short.name} [{SCGMgmtIp}]
because [{cause}]. Accounting session locally cleared
This event occurs when the controller does not receive a response or receives an
error response for accounting stop. This event is applicable for TTG/PDG
provided accounting process is enabled for the session.
Accounting session interim failed
accSessInterimFail
1248
Debug
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide