Alarm Types
Cluster Alarms
TABLE 54 Cluster node shut down alarm (continued)
Alarm
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions
Disk usage exceed threshold
TABLE 55 Disk usage exceed threshold alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Attribute
Displayed on the web
interface
Description
Recommended Actions
Cluster out of service
TABLE 56 Cluster out of service alarm
Alarm
Alarm Type
Alarm Code
Severity
Aggregation Policy
Auto Clearance
Attribute
Displayed on the web
interface
Description
Recommended Actions
84
Cluster node shut down
From the event code 828 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 826.
"nodeName"="xxx", "nodeMac"="xx:xx:xx:xx:xx:xx "
Node [{nodeName}] has been shut down
This alarm is triggered when the node shutdowns.
This usually occurs due to a user action. Please send the log files stored in the
path - /opt/ ruckuswireless/controller/log/system to Ruckus
support for analysis.
Disk usage exceed threshold
diskUsageExceed
834
Critical
From the event code 838 an alarm is raised for every event. A single event
triggers a single alarm.
"nodeName"="xx", "status"="xx"
The disk usage of node [{nodeName}] is over {status}%.
This alarm is triggered when the disk usage has reached the threshold limit. The
disk usage percentage can be configured from 60% to 90%.
It is recommended that the user moves the backup files to the FTP server and
deletes the moved backup files.
Cluster out of service
clusterOutOfService
843
Critical
From the event code 843 an alarm is raised for every event. A single event
triggers a single alarm.
The alarm code is auto cleared with the event code 808.
"clusterName"="xx"
Cluster [{clusterName}] is out of service.
This alarm is triggered when the cluster service fails.
It is recommended that the operator or user checks the out of service node to
locate the reason.
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A
Need help?
Do you have a question about the Virtual SmartZone High Scale and is the answer not in the manual?