11)
Check the height between Finisher and the Host Machine.
CAUTION:
Height difference should be within +/-2 mm. Execute "Height Adjustment" if the
difference is +/-2 mm or more.
Finisher
12)
Attach the Rear Small Cover.
• 1 Screw
13)
Remove the Screw on the rear lower of the Host Machine. (Removed Screw will be
used in step 14).)
7
Installation > Installation Procedure > Connecting with the Host Machine
Host Machine
F-7-31
7
Installation > Installation Procedure > Connecting with the Host Machine
14)
Install the Shunt Cable.
• 1 Screw (The Screw remove in step 13).)
• 1 Screw (RS tighting; M4x10)
x2
F-7-32
Shunt Cable
F-7-33
7-14