5
Adjustment > Adjustment at Time of Parts Replacement > Adjustment in the Case of Canceling Limit for Tray Stack > Procedure
2) Press switch SW385 [1] so that this adjustment is ready now.
SW382
SW381
SW383
SW384 SW385
(-)
(+)
3) Pressing push switch SW384 [1] once displays "+1" on the LED [2].
SW382
SW381
SW383
SW384 SW385
(-)
(+)
5
Adjustment > Adjustment at Time of Parts Replacement > Adjustment in the Case of Canceling Limit for Tray Stack > Procedure
ENTER
[1]
F-5-143
[2]
ENTER
[1]
F-5-144
4) Press switch SW385 [1] again to complete this adjustment.
SW382
SW381
SW383
SW384 SW385
(-)
(+)
ENTER
[1]
F-5-145