DIPSW(SW382)
1
2
3
4
5
6
7
8
-
-
-
On -
On -
On -
Staple clinch
-
-
-
On -
On On -
M7
Horizontal
registration shift
motor
-
-
-
On -
On On On M6
Horizontal
registration detection
unit move motor
-
-
-
On On -
-
-
M8
Feed roller
disengage motor
-
-
-
On On -
-
On M20
Upper guide motor
-
-
-
On On -
On -
M24
Punch motor
-
-
-
On On -
On On M28
Delivery angle
adjustment motor
-
-
-
On On On -
-
M27
Inlet roller disengage
motor
-
-
On -
-
-
-
-
M22
Tray A lift motor
-
-
On -
-
-
-
On M23
Tray B lift motor
-
-
On -
-
-
On On FM5
Upper Delivery Fan After pressing ENTER to start the
6
Troubleshooting > Drive/Sensor check > Motor,Solenoid
Name
details
After pressing ENTER to start the
motor, use + (rear)/- (front) to move
15 mm (3 locations at rear, center and
front). Press ENTER again to terminate
the motor (Home).
After pressing ENTER to start the
motor, use + to perform detection
(to move maximum of 14 mm in the
direction of paper edge) or - to move to
the position which is 80 mm from HP.
Press ENTER again to terminate the
motor (Home).
After pressing ENTER to start
the motor, use + (to engage)/- (to
disengage). Press ENTER again to
terminate the motor (Home).
After pressing ENTER to start the
motor, use + (Up)/- (Home). Press
ENTER again to terminate the motor
(Home).
After pressing ENTER to start the
motor, use + (to punch)/- (to switch
between 2/3-hole or 2/4-hole). Press
ENTER again to terminate the motor.
After pressing ENTER to start the
motor, use + (through delivery angle)/-
(stack delivery angle). Press ENTER
again to terminate the motor (Home).
After pressing ENTER to start
the motor, use + (to engage)/- (to
disengage). Press ENTER again to
terminate the motor (Home).
After pressing ENTER to start the
motor, use + (Down)/- (Up) to move 20
mm. Press ENTER again to terminate
the motor.
After pressing ENTER to start the
motor, use + (Down)/- (Up) to move 20
mm. Press ENTER again to terminate
the motor.
fan, use +/- to operate it in units of
5.8*(5*(10/255)) [V] in the range of
0 to 29 [V]. Press ENTER again to
terminate the fan.
6
Troubleshooting > Drive/Sensor check > Motor,Solenoid
DIPSW(SW382)
1
2
3
4
5
6
7
8
-
-
On -
-
On -
-
FM6
Lower Delivery Fan After pressing ENTER to start the
-
-
On -
-
On On On M201 Stack Retainer
Motor
-
-
On -
On -
-
-
M202
"Upper Neat Stack
M205
Unit Front Alignment
Moter
Lower Neat Stack
Unit Front Alignment
Moter"
Name
details
fan, use +/- to operate it in units of
5.8*(5*(10/255)) [V] in the range of
0 to 29 [V]. Press ENTER again to
terminate the fan.
"After pressing ENTER to start the
motor, use + to select the mode (A:
Operation check/B: HP adjustment/C:
Pressure adjustment/D: Middle position
adjustment/E: Corrugation position
adjustment)
Operation check: Every press of
ENTER changes the position as
follows; stack retaining position =>
HP => middle position => HP =>
corrugation position => HP. Then, the
operation check is terminated.
HP adjustment: Use +/- to adjust the
position in units of 1 pls. Press ENTER
again to terminate the adjustment. The
range of values: +/-3
Pressure adjustment: Use +/- to
adjust the pressure in units of 3 pls.
Press ENTER again to terminate the
adjustment. The range of values: +/-9
Middle position adjustment: Use +/-
to adjust the position in units of 3 pls.
Press ENTER again to terminate the
adjustment. The range of values: +/-9
Corrugation position adjustment: Use
+/- to adjust the position in units of 1
pls. Press ENTER again to terminate
the adjustment. The range of values: -6
to 12
"
After pressing ENTER to start the
motor, use + to select upper or lower
(0: Upper Neat/1: Lower Neat).
Every press of ENTER changes
the operation as follows; Alignment
Plate phase alignment => Alignment
Plate positioning => Alignment Plate
initialization Then, use +/- to move 21
mm. Press ENTER again to terminate
the motor.
6-4